亚洲一区二区三区麻豆,日本一区不卡在线观看,蜜桃久久麻豆传媒,午夜成人视频官方版

本站熱搜:氧化鋯氧量分析儀,盤裝式氧量分析儀,電磁流量計(jì),WSS雙金屬溫度計(jì)
  • 技術(shù)文章ARTICLE

    您當(dāng)前的位置:首頁 > 技術(shù)文章 > Common faults and causes of zirconia oxygen analyzers

    Common faults and causes of zirconia oxygen analyzers

    發(fā)布時(shí)間: 2024-12-13  點(diǎn)擊次數(shù): 1741次

    1. System maintenance.

    If the oxygen indicator shows zero or no oxygen indication in the oxygen quantity converter, first check whether the oxygen indication circuit open. If the circuit is normal, check whether the zirconia probe is normal. At a temperature of 700℃, measure the DC millolt value of the oxygen cell. If the potential is greater than 1 millivolt and the resistance is greater than 100Ω, it indicates the probe is aged and needs to be replaced with a sensor or probe. If the potential is less than 1 millivolt and the resistance is less than100Ω, it indicates an open circuit in the wiring, which should be checked and handled one by one.

    2. constant temperature system failure.

    (1) If the heating temperature cannot be maintained, check whether there is a short circuit or open circuit in the resistance wire inside the heating furnace The normal resistance of the heating furnace wire is about 60-80Ω. If the resistance wire is open or the resistance measured by the multimeter less than 60Ω, the heating furnace wire should be replaced.

    (2) When the converter shows that the temperature is too high or out of control, it not only causes inaccurate oxygen display but also acceler the aging or damage of the zirconia head. At this point, you should immediately check if the thermocouple is open-circuited, or a multimeter to check the thermocouple. If the resistance is greater than 20Ω, it is judged that the thermocouple is open-cuited, and the thermocouple and zirconia head should be replaced; another reason for the temperature失控is: relay or temperature control circuit failure, relay or temperature control circuit failure will cause the oxygen converter to always be in one of the heating voltages of the heating furnace, thus leading to an increase in.

    3. oxygen cell fault.

    (1) After the oxygen cell has been used for a period of time, the contact points of its leads may become oxidized, resulting in contact or detachment. This can cause the Em value (in units of a multimeter) to fluctuate and become unstable. Observe the oxygen cell and take action.

    (2) When the oxygen signal deviation is too large or inaccurate, it may be due to a short circuit in the zirconia electrode, which case the wiring of the zirconia cell should be checked for short circuits. When the temperature does not rise, if the internal resistance is less than 0Ω, it indicates a short circuit in the electrode, and the zirconia head needs to be replaced.

    (3) During the operation of the oxygen measurement device, if the background potential exceeds 10mV or is less than -30mV, it must be recalibrated. If the background potential remains abnormal after calibration, it indicates that the probe has aged and can no longer be used.

    4. pneumatic circuit failure.

    (1) The zirconia head is clogged with ash, causing an obstruction in the reference gas circulation. This results in a decrease in probe output potential Em and an increase in the background potential Eo. In this case, blowing several times with a bulb syringe at the gas inlet of the will resolve the issue after the gas line is unclogged.

    (2) Oxygen cell ash blockage: The probe should be removed from the ash blockage and the filter should be reinstalled.

    (3) Probe leakage has a significant impact on the probe.

    5. The oxygen content on both sides of the boiler is too high.

    By adjusting the boiler combustion conditions, when starting or stopping the boiler fan or coal mill group, if the oxygen content deviation on both sides of the boiler is large, it is a normal phenomenon. Once the boiler combustion conditions stabilize, the oxygen content display will return to normal. If the unit adjustment is not in place and the deviation is large on both sides, it is necessary to check if the zirconia head is working properly by dismantling the transmitter for inspection. The device requires the operator to adjust the gas flow. The gaseous and reference state gases should continuously flow through the electrode without stopping, and there should be no dead ends. However, too large a flow will have a cooling effect, making the cell temperature uneven and causing errors. If the flow is too small, it is not only easy to form stagnant gas flow and dead zones but also may cause local changes in oxygen concentration due to the conduction of oxygen ions, thus affecting the accuracy of the measurement and causing deviations on both sides.

    6. On-site interference causes failures.

    For newly installed instruments, due to the strong electromagnetic field, when an unstable fault occurs, the first thing to consider is the interference issue.


產(chǎn)品中心 Products
在線客服 聯(lián)系方式 二維碼

服務(wù)熱線

0550-2409223

掃一掃,關(guān)注我們

皖公網(wǎng)安備 34118102000850號(hào)

被误解的日本“变态”色情行业的一生| 国产日韩精品欧美| 探索优质国产影视内容观看体验提升之道 | 精品这里只有精品| 《色老大》完整版剧情720P在线观看 | 手机91精品视频| 热人妻偷产国产魅力四溢心动瞬间| 日本一区二区三区在线网最新版v 日本一区二区三区在线网最新版 免费观看黄A片在线观看 | 日韩手机免费播放| 自拍合集自拍| 2020自拍系列精品视频| 国产精品99久久久久久久宅男| 伊人久久亚洲漾| 精品高清一区二区三区| 亚洲永久久久无码| 五六月丁香视频六月激情久久婷婷| 成人视频网站免费在线看| 牲高潮99爽久久久久777| 国产有码av在线播放| 韩国午夜福利av| 精品经典玖玖玖| 大香蕉在线伊人视频75| 好健康好吊妞这里只有一| 深爱激动情一区二区三区| 91香蕉视频在线下载| 欧美午夜精选久久久| 欧美大香蕉视频| 日韩精品无码一区二区三区在| 久久精品亚洲AV无码一区二区三区 | 青青青免费观看在线视频网站| 《欧美日韩》电视剧在线观看| 757午夜福利92看看AV成人| 午夜成人免费视频| 又大又硬还爽高潮免费视频| 精品少妇一区二区三区| 亚洲永久久久无码| 全集电影高清完整版在线看| 中文字幕手机在线播放| 《艹比视频》电影无删减手机免费播放| 亚洲色一区二区三区四区| 老司机无码精品A|